In three - phase electrical circuits, there is often the need to transform from a Delta configuration to a Star configuration and vice versa. The formulas for making these conversions are detailed below:
For a Star  to Delta Transformation, as shown in the formula above:



Z_{12} = Z_1 + Z_2  + \frac{Z_1 Z_2}{Z_3}

Z_{23} = Z_2 + Z_3  + \frac{Z_2 Z_3}{Z_1}

Z_{13} = Z_3 + Z_1  + \frac{Z_3 Z_1}{Z_2}




For a Delta to Star Transformation, we have:
Z_1 = \frac{Z_{12} Z_{13}}{Z_{12}+Z_{13}+ Z_{23}}

Z_2 = \frac{Z_{12} Z_{23}}{Z_{12}+Z_{13}+ Z_{23}}

Z_3 = \frac{Z_{23} Z_{13}}{Z_{12}+Z_{13}+ Z_{23}}


With the above formulas, you can easily transform from a Delta configuration to a Star configuration or vice versa.